These instructions help you configure your LG iPECS phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

<a id="Configure the SMDR output"></a>

Configure the SMDR output

The SMDR output in LG iPECS is disabled by default. To enable the output, you need to amend the settings under the following programming codes:

SMDR Attributes (PGM 177)

Save Enable: Leave this as the default which is unticked
Print Enable: This needs to be enabled by clicking on the check box
SMDR Record Call Type: This needs to be set to 'All Calls', you will need to select this from the drop-down list
Records In Detail: This needs to be enabled by clicking on the check box
Print Incoming Call: This needs to be enabled by clicking on the check box
Print Lost Call: This needs to be enabled by clicking on the check box
SMDR Dial Digit Hidden: Leave this as the default which is '0'
SMDR Currency Unit: Leave this as the default which is blank
SMDR Cost Per Metering Pulse: Leave this as the default which is blank
SMDR Fraction: Leave this as the default which is '0'
SMDR Start Time: Leave this as the default which is '0'
SMDR Hidden Digit: Leave this as the default which is 'Right'
Long Distance Call Digit Counter: Leave this as the default which is '0'
Long Distance Code (Max 2 Digits): Leave this as the default
MSN Print on SMDR: Leave this is the default which is unticked
Print Caller Number: This needs to be enabled by clicking on the check box

Here is an example of a populated SMDR Attributes screen:

Printer Port Selection (PGM 175)

In the  window, set Info/On-line SMDR to Serial 1 to send call logging data by serial port.

ISDN Attributes (PGM 200)

To enable CLI information in the call records produced by your LG iPECS, you need to set the  to , as shown below:

<a id="Install NetPBX"></a>

Installing NetPBX

Install and configure NetPBX

<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once NetPBX is configured and collecting data, log in to TIM Plus and perform the following steps:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.
  3. In the Site Properties window, select LG iPECS from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.