These instructions help you configure your LG IPLDK phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
<a id="Configure the SMDR output"></a> |
The SMDR output on the LG IPLDK is disabled by default. To enable the output, you need to amend the following settings in the programming sections below:
In the Print Serial Port Selection (PGM 175) window, set Info/On-line SMDR to COM1/COM2 to enable output to serial port.
Save Enable: This needs to be disabled
Print Enable: This needs to be enabled
SMDR Record Call Type: This needs to be set to 'All Calls'
Records In Detail: This needs to be enabled
Print Incoming Call: This needs to be enabled
Print Lost Call: This needs to be enabled
SMDR Dial Digit Hidden: Leave this as the default which is '0'
SMDR Currency Unit: Leave this as the default which is blank
SMDR Cost Per Metering Pulse: Leave this as the default which is blank
SMDR Fraction: Leave this as the default which is '0'
SMDR Start Time: Leave this as the default which is '0'
SMDR Hidden Digit: Leave this as the default which is 'Right'
Long Distance Call Digit Counter: Leave this as the default which is '0'
Long Distance Code (Max 2 Digits): Leave this as the default
MSN Print on SMDR: This needs to be disabled
Print Caller Number: This needs to be disabled
Enable the CLI Print to serial field, as shown the ISDN Attributes window below:
<a id="Install NetPBX"></a> |
If your LG IPLDK has been configured to send SMDR data via a serial connection, you first need to install the NetPBX software to collect the data from the serial port and send it to TIM Plus. For setup instructions, click on the link below:
<a id="Configure TIM Plus"></a> |
Once NetPBX is configured and collecting data, log in to TIM Plus and perform the following steps: