These instructions help you configure your Samsung DCS phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
<a id="Configure the SMDR output"></a> |
Follow the instructions below to configure your Samsung DCS to output SMDR data to TIM Plus. The configuration needs to be performed from a LCD handset.
Program each option as presented below:
SMDR field | Value |
---|---|
Page Header | Yes |
Lines per page | 1 |
Incoming Call | Yes |
Outgoing Call | Yes |
Authorise Code | Yes |
SMDR Start Time | Yes |
In/Out Group | No |
DND Calls | No |
Wake-Up Calls | No |
Directory Names | None |
Caller ID Data | Yes |
Abandoned Call | Yes |
No of Dial Mask | 00 |
DID Num/Name | Yes |
<a id="Install NetPBX"></a> |
The Samsung DCS phone system sends SMDR data via a serial connection. To collect the data from the serial port and send it to TIM Plus, you first need to install the NetPBX software. For setup instructions, click on the link below:
<a id="Configure TIM Plus"></a> |
Once NetPBX is configured and collecting data, log in to TIM Plus and perform the steps below: