These instructions help you configure your Splicecom Maximiser phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
<a id="Configure the SMDR output"></a> |
Configuring the SMDR output
By default, the call logging output of the Splicecom Maximiser is enabled and you do not normally require a password to obtain it. To protect your call logging data, you can set a in the screen of your Maximiser's web management interface. If you decide to set a password, you need to enter this when configuring TIM Plus (below).
Your system maintainer may have already set a call logging password for you. |
<a id="Configure TIM Plus"></a> |
Configuring TIM Plus
Follow the steps below to configure TIM Plus to collect call logging data from your Splicecom Maximiser:
- Click on the Directory tab.
- Choose the site you want to configure and click Properties.
- In the Site Properties window, select Splicecom Maximiser from the PBX model drop-down list.
- In the Connection method field, select Actively connect to PBX from the drop-down list.
- In the Host field, enter the IP address of your Splicecom Maximiser.
- In the Port field, enter 4001.
- Leave the Username field blank.
- If your Maximiser has a set, enter it in Password field; if not, leave it blank.
- In the Connection script field, select SpliceCom Maximiser from the drop-down list.
- Click on the Save button to apply the changes.