These instructions help you configure your NEC NEAX phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

<a id="Configure the SMDR output"></a>

Configuring your SMDR output

Using the Customer Administration Terminal (CAT), enter the following settings in the system-programming mode:

Field nameDetails
CM40Default output port and attributes: 9600 baud, 8 data bits, no parity, 2 stop bits, DTR/RTS flow control.
CM13+05Enable SMDR for incoming calls to required stations.
CM13+06Enable SMDR for outgoing calls to required stations.
CM35+14Enable SMDR for outgoing calls to required trunk routes.
CM35+49Enable SMDR for incoming calls to required trunk routes.
CM08

If SMDR for incoming calls is enabled, specify whether the setting applies to all incoming calls or only to those that use account codes. Also, include ANI/Caller ID for incoming calls.

NOTE 1: The ANI/Caller ID is required to provide SMDR data for incoming calls, even if this feature is enabled by CM13+05 and CM35+49.

NOTE 2: Use CDR formats #501 (2400 IMS), #505 (2000 IPS), #506 (2000 IVS).

 

<a id="Install NetPBX"></a>

Installing NetPBX

Install and configure NetPBX

<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Once NetPBX is configured and collecting data, log in to TIM Plus and perform the steps below:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and clickProperties.
  3. In the Site Properties window, select NEC NEAX from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.