These instructions help you configure your Cisco UCME / UC500 to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
<a id="Configure UCME to send RADIUS events"></a> |
Use Telnet to connect to the IP address of your UCME as shown below:
Once connected, enter the following commands to enable the UCME to send RADIUS events to TIM Plus:
Step | IOS commands | Description |
---|---|---|
1 | enable | Causes the UCME to enter EXEC mode. Type your EXEC password if requested |
2 | conf t | Enters the global configuration mode |
3 | aaa new-model | Enables aaa accounting mode |
aaa accounting connection h323 start-stop group RADIUS | ||
gw-accounting aaa | ||
acct-template callhistory-detail | ||
4 | RADIUS-server host 192.168.0.1 auth-port 0 acct-port 1612 | Specifies the IP address and port of TIM Plus's RADIUS, to which CDR data will be sent, e.g. |
5 | RADIUS-server key C1sco | Specifies a RADIUS authentication secret that will be used by TIM Plus (configured in the next section), e.g. |
6 | RADIUS-server vsa send accounting | Enables VSA events |
7 | end | Exits configuration mode |
8 | wr | Saves the changes |
<a id="Configure Cisco AXL sync"></a> |
Follow the steps below to configure TIM Plus to perform directory synchronisation with your Cisco UCME:
<a id="Configure TIM Plus to capture RADIUS packets"></a> |
Follow the steps below to configure TIM Plus to receive RADIUS data from your UCME:
In the Client IP field, enter the IP address of your UCME.
In the Secret field, enter the RADIUS-server key you configured on your UCME in the section above, e.g. C1sco.
Click on the
button to apply the settings.