These instructions help you configure your Siemens OpenOffice phone system to work with TIM Enterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.

<a id="Configure the SMDR output"></a> |
Configuring your SMDR output
By default, the SMDR output of a Siemens OpenOffice phone system is not enabled. For information about how to configure the output for incoming, outgoing and internal calls, contact your system maintainer.
<a id="Set up a DSN connection"></a> |
Setting up a DSN connection
To enable TIM Enterprise to work with the Siemens OpenOffice, you first need to set up a DSN connection, by following the steps below:
- Open Windows Control Panel
- Double-click on the Administrative tools icon
Double-click on the Data Sources (ODBC) icon to open the ODBC Data Source Administrator window
For a 64 bit system, access the ODBC Data Source Administrator from the following location C:\Windows\SysWOW64\odbcad32.exe |
- Click on the System DSN tab
- Click on the Add button
- Select Native from the driver list and click Finish
- In the Data source name field enter Siemens OpenOffice
- Click on the OK button to save the changes
An example of an ODBC entry is shown below:

<a id="Configure the interface file"></a> |
Configuring the interface file
Follow the steps below to configure the interface file to establish an HTTPS connection with your Siemens OpenOffice:
- Open the
file, located by default in
. - Edit the file to point to the IP address of your Siemens OpenOffice and enter the relevant username and password, as shown below.

- Remove the apostrophe (') in front of the amended fields to enable them. An example of a configured interface file is shown below:

<a id="Configure TIM Enterprise"></a> |
Configuring TIM Enterprise
Once the DSN connection has been set up, log in to TIM Enterprise and perform the following steps:
- Click on the Directory tab.
- Locate the PBX object you want to configure in the Directory, right-click on it and select Properties.
- A new window will open displaying the general properties of your PBX object. Select Siemens OpenOffice from the Data format list from the right-hand side, as shown below:

- Click on the Connection tab and select System DSN connection from the Connection method list.
- In the DSN field, select Siemens OpenOffice from the drop-down list.
- In the Frequency field, enter 5 to check for data every five seconds.
- In the DB script field, select Siemens from the drop-down list.
- Click on the Save button to apply the settings.
