<p>These instructions should assist in configuring your Aastra BP to work with TIM Enterprise. If you are not familiar with PBX configuration, please contact your system maintainer.</p> <table class="confluenceTable"> <tbody> <tr> <th class="confluenceTh" width=158>Connection information</th> <th class="confluenceTh">Description</th> </tr> <tr> <td class="confluenceTd"><b>Connection type</b></td> <td class="confluenceTd"><b>Serial Output: </b> As the Aastra BP sends SMDR information via a serial connection which is located on BP unit itself, you will need to directly connect a serial cable from the Aastra BP to the PC that NetPBX is installed and running on. </td> </tr> <tr> <td class="confluenceTd"><b>Cable configuration</b></td> <td class="confluenceTd">Null-modem/Crossover. </td> </tr> </tbody> </table> <h2>Configuring your SMDR</h2> <h4>BP firmware R12 or older</h4> <p>If you are using firmware which is older than R12 you need to setup the SMDR output to CIL3.</p> <h4>BP firmware R13+</h4> <p>If you are using firmware R13+ you will need to set the SMDR output to 'Flexible CIL' and configure the options as below:</p> <img src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/aastra_bp_1.png" alt="Aastra BP" /> <h2>Configuring TIM Enterprise</h2> <p>Below you will find steps on how to configure TIM Enterprise to listen for SMDR data from your Aastra BP:</p> <ol> <li>Browse to TIM Enterprise as normal and login with your credentials.</li> <li>Click on the <span class="button" id="list">Directory</span> tab.</li> <li>Go the the point in the Directory where you need to add the PBX Object and add a PBX with the name 'Siemens HiCom-HiPath'.</li> <li>Left-click on it and select <span class="button" id="list">Properties</span>.</li> <li>From the <span class="button" id="list">General</span> settings tab select <span class="keyword">Siemens HiCom-HiPath</span> from the PBX model list.</li> <img src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/aastra_bp_2.png" alt="Aastra BP" /> <li>In the <span class="button" id="list">Connection</span> tab select <span class="keyword">No connection required</span> from the <span class="reference">Connection method</span> list.</li> <li>Finally, click on the <span class="button" id="list">Save</span> button.</li> <img src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/aastra_bp_3.png" alt="Aastra BP" /> </ol> |