Skip to end of metadata
Go to start of metadata

These instructions help you configure your LG iPECS phone system to work with TIM Enterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Connection Type
  TIM Enterprise establishes a TCP connection to this PBX.

Support Files
  LG iPECS.TDT
  LG.TDS
Required Tasks
  Configure the SMDR output
  Configure TIM Enterprise

Configuring the SMDR output

The SMDR output in LG iPECS is disabled by default. To enable the output, you need to amend the following settings in the programming sections below:

SMDR Attributes (PGM 177)
FieldDescription
Save EnableLeave this as the default, which is unticked
Print EnableThis needs to be enabled by clicking on the check box
SMDR Record Call TypeThis needs to be set to 'All Calls', you will need to select this from the drop-down list
Records In DetailThis needs to be enabled by clicking on the check box
Print Incoming CallThis needs to be enabled by clicking on the check box
Print Lost CallThis needs to be enabled by clicking on the check box
SMDR Dial Digit HiddenLeave this as the default which is '0'
SMDR Currency UnitLeave this as the default which is blank
SMDR Cost Per Metering PulseLeave this as the default which is blank
SMDR FractionLeave this as the default which is '0'
SMDR Start TimeLeave this as the default which is '0'
SMDR Hidden DigitLeave this as the default which is 'Right'
Long Distance Call Digit CounterLeave this as the default which is '0'
Long Distance Code (Max 2 Digits)Leave this as the default
MSN Print on SMDRLeave this is the default which is unticked
Print Caller NumberThis needs to be enabled by clicking on the check box

Here is an example of a populated  SMDR Attributes screen:


Printer Port Selection (PGM 175)

In the Printer Port Selection (PGM 175) window, set Info/On-line SMDR to Telnet 1 to send call logging data to TIM Enterprise over TCP to port 23.

ISDN Attributes (PGM 200)

To enable CLI information in the call records produced by your LG iPECS, you need to set the CLI Print To Serial to ON, as shown below:


Configuring TIM Enterprise

Follow the steps below to configure TIM Enterprise to collect the SMDR data from your LG iPECS:

  1. Click on the Directory tab.
  2. Locate the PBX object you want to configure in the Directory, right-click on it and select Properties.
  3. A new window will open, displaying the general properties of your PBX object. Select LG iPECS from the Data format list and tick the Keep a local backup of data box, as shown below:

  4. Click on the Connection tab and select Establish TCP connection to PBX from the Connection method list.
  5. In the Host field, enter the IP address of your LG iPECS.
  6. In the Port field, enter 23.
  7. Leave the Username and Password fields blank.
  8. In the IP script field, select Generic Simple from the drop-down list.
  9. Click on the Save button to apply the settings.


 

Labels: