These instructions help you configure your LG iPECS phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type
TIM Plus establishes a TCP connection to this PBX.Support Files
LG iPECS.TDTLG.TDS
Required Tasks
Configure the SMDR outputConfigure TIM Plus
Configuring the SMDR output
The SMDR output in LG iPECS is disabled by default. To enable the output, you need to amend the following settings in the programming sections below:
SMDR Attributes (PGM 177)
Field | Description |
---|---|
Save Enable | Leave this as the default, which is unticked |
Print Enable | This needs to be enabled by clicking on the check box |
SMDR Record Call Type | This needs to be set to 'All Calls', you will need to select this from the drop-down list |
Records In Detail | This needs to be enabled by clicking on the check box |
Print Incoming Call | This needs to be enabled by clicking on the check box |
Print Lost Call | This needs to be enabled by clicking on the check box |
SMDR Dial Digit Hidden | Leave this as the default which is '0' |
SMDR Currency Unit | Leave this as the default which is blank |
SMDR Cost Per Metering Pulse | Leave this as the default which is blank |
SMDR Fraction | Leave this as the default which is '0' |
SMDR Start Time | Leave this as the default which is '0' |
SMDR Hidden Digit | Leave this as the default which is 'Right' |
Long Distance Call Digit Counter | Leave this as the default which is '0' |
Long Distance Code (Max 2 Digits) | Leave this as the default |
MSN Print on SMDR | Leave this is the default which is unticked |
Print Caller Number | This needs to be enabled by clicking on the check box |
Here is an example of a populated SMDR Attributes screen:
Printer Port Selection (PGM 175)
In the Printer Port Selection (PGM 175) window, set Info/On-line SMDR to Telnet 1 to send call logging data to TIM Plus over TCP to port 23.
ISDN Attributes (PGM 200)
To enable CLI information in the call records produced by your LG iPECS, you need to set the CLI Print To Serial to ON, as shown below:
Configuring TIM Plus
If your LG iPECS has been configured to send its call logging data via TCP/IP, follow the steps below to configure TIM Plus:
- Click on the tab.
- Choose the site you want to configure and click
. - In the Site Properties window, select LG iPECS from the PBX model drop-down list.
- In the Connection method field, select Actively connect to PBX from the drop-down list.
- In the Host field, enter the IP address of your LG iPECS.
- In the Port field, enter 23.
- Leave the Username and Password fields blank.
- In the Connection script field, select Generic Simple from the drop-down list.
- Click on the button to apply the settings.