These instructions help you configure your Avaya BCM 4(v4.x0+) phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
...
HTML |
---|
<a id="Configure the SMDR output"></a> |
Configuring your SMDR output
Below you will find instructions on how Follow the steps below to configure your Avaya BCM v4.x+ to output SMDR data to TIM Plus:
- Login Log in to the BCM Element Manager.
- On the Task Navigation Panel, click the tab.
- Click on .
Click on .
On the right-hand side the Call Detail Recording window will appear.
In the Call Detail Recording window panel that appears, configure the options as below:
SMDR field Value Format Norstar Report Type All Language English Date Format MM/DD/YY Header Format Line/Station Filter Type All Feature Code F9 Leave as default Minimum Call Duration Leave as default Hospitality Records Leave as default Include DNIS Info Enable Include CLID with call type Enable Include Long CLID Leave as default Use answer supervision Leave as default Display connection character Leave as default Suppress digits after connect Leave as default Maximum digits after connect Leave as default
HTML |
---|
<a id="Configure a CDR user"></a> |
CDR User
To enable TIM Plus to connect to your your Avaya BCM v4.x+, you will need to create a
Referencemacro | ||
---|---|---|
|
Buttonmacro | ||
---|---|---|
|
HTML |
---|
<a id="Configure TIM Plus"></a> |
Configuring TIM Plus
Below you will find steps on how to configure TIM Plus to collect the SMDR data from your Avaya BCM:
...