These instructions help you configure your Avaya BCM 4(v4.x0+) phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

...

HTML
<a id="Configure the SMDR output"></a>

Configuring your SMDR output

Below you will find instructions on how Follow the steps below to configure your Avaya BCM v4.x+ to output SMDR data to TIM Plus:

  1. Login Log in to the BCM Element Manager.
  2. On the Task Navigation Panel, click the Configuration tab.
  3. Click on Telephony.
  4. Click on Call Detail Recording.

  5. On the right-hand side the Call Detail Recording window will appear.

  6. In the Call Detail Recording window panel that appears, configure the options as below:

    SMDR fieldValue
    FormatNorstar
    Report TypeAll
    LanguageEnglish
    Date FormatMM/DD/YY
    Header FormatLine/Station
    Filter TypeAll
    Feature Code F9Leave as default
    Minimum Call DurationLeave as default
    Hospitality RecordsLeave as default
    Include DNIS InfoEnable
    Include CLID with call typeEnable
    Include Long CLIDLeave as default
    Use answer supervisionLeave as default
    Display connection characterLeave as default
    Suppress digits after connectLeave as default
    Maximum digits after connectLeave as default
HTML
<a id="Configure a CDR user"></a>

CDR User

To enable TIM Plus to connect to your  your Avaya BCM v4.x+, you will need to create a

Referencemacro
LabelCDR User
in your phone system. This can be configured within your Business Communications Manager Unified Manager appliction, under  under the 
Buttonmacro
LabelSystem
options option in the Business Communications Manager Unified Manager configuration utility.

HTML
<a id="Configure TIM Plus"></a>

Configuring TIM Plus

Below you will find steps on how to configure TIM Plus to collect the SMDR data from your Avaya BCM:

...