<p>These instructions should assist in configuring your Panasonic KX-TA/E to
work with TIM Enterprise. If you are not familiar with PBX
configuration, please contact your system maintainer.</p>
<table class="confluenceTable">
<tbody>
<tr>
<th class="confluenceTh" width=158>Connection information</th>
<th class="confluenceTh">Description</th>
</tr>
<tr>
<td class="confluenceTd"><b>Connection type</b></td>
<td class="confluenceTd"><b>Serial Output: </b>
Panasonic KX-TA/E PBX sends SMDR information via a serial connection. You will need to directly connect a serial cable from the Panasonic KX-TA/E PBX to the PC that NetPBX is installed and running on.
</td>
</tr>
<tr>
<td class="confluenceTd"><b>Cable configuration</b></td>
<td class="confluenceTd"> Null-Modem/Crossover.
</td>
</tr>
</tbody>
</table>
<h2>Configuring your SMDR</h2>
<p>Below you will find instructions on how to configure your Panasonic
KX-TA/E to output SMDR to TIM Enterprise, you will need to do this from
the Panasonic KX-T7130 phone:</p>
<ol>
<li>On the back of the phone set it to <span class="reference">Program</span>.</li>
<li>Press <span class="keyword">- *</span> and then <span class="button" id="list"no_margin">#</span> key and enter your system password.</li>
<li>Press <span class="keyword">##</span>. You are now in <i>Programming mode</i>.</li>
<li>Go to programming code <span class="keyword">800</span>, and set each of settings as below, after you have set each one press <span class="button" id="list"no_margin">Store</span> and then
<span class="button" id="list"no_margin">Next</span> to move to the next setting:</li>
<table class="confluenceTable">
<tbody>
<tr>
<th class="confluenceTh" width=158>SMDR field</th>
<th class="confluenceTh">Value</th>
</tr>
<tr>
<td class="confluenceTd"><b>NL-Code</b></td>
<td class="confluenceTd"><span class="keyword">CR+LF</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Baud Rate</b></td>
<td class="confluenceTd"><span class="keyword">9600</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Word Length</b></td>
<td class="confluenceTd"><span class="keyword">8 bits</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Parity</b></td>
<td class="confluenceTd"><span class="keyword">None</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Stop Bit</b></td>
<td class="confluenceTd"><span class="keyword">1 bit</span></td>
</tr>
</tbody>
</table>
<li>Go to programming code <span class="keyword">801</span>, and set each of settings as below, after you have set each one press <span class="button" id="list"no_margin">Store</span> and then
<span class="button" id="list"no_margin">Next</span> to move to the next setting:</li>
<table class="confluenceTable">
<tbody>
<tr>
<th class="confluenceTh" width=158>SMDR field</th>
<th class="confluenceTh">Value</th>
</tr>
<tr>
<td class="confluenceTd"><b>Page Length</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
<tr>
<td class="confluenceTd"><b>Skip Perf</b></td>
<td class="confluenceTd">Leave as default</td>
</tr>
</tbody>
</table>
<li>Go to programming code <span class="keyword">802</span>, and set each of settings as below, after you have set each one press <span class="button" id="list"no_margin">Store</span> and then
<span class="button" id="list"no_margin">Next</span> to move to the next setting:</li>
<table class="confluenceTable">
<tbody>
<tr>
<th class="confluenceTh" width=158>SMDR field</th>
<th class="confluenceTh">Value</th>
</tr>
<tr>
<td class="confluenceTd"><b>Outgoing</b></td>
<td class="confluenceTd"><span class="keyword">On</span></td>
</tr>
<tr>
<td class="confluenceTd"><b>Incoming</b></td>
<td class="confluenceTd"><span class="keyword">On</span></td>
</tr>
</tbody>
</table>
<li>On the back of the phone set it back to <span class="button" id="list"no_margin">Store</span>.</li>
</ol>
<h2>Configuring TIM Enterprise</h2>
<p>Below you will find steps on how to configure TIM Enterprise to listen for SMDR data from your Panasonic KX-TA/E:</p>
<ol>
<li>Browse to TIM Enterprise as normal and login with your credentials.</li>
<li>Click on the <span class="button" id="list"no_margin">Directory</span> tab.</li>
<li>Go the the point in the Directory where you need to add the PBX Object and add a PBX with the name 'Panasonic KX-TA/E'.</li>
<li>Left-click on it and select <span class="button" id="list"no_margin">Properties</span>.</li>
<li>From the <span class="button" id="list"no_margin">General</span> settings tab select your <span class="keyword">Panasonic KX-TD Series</span> family PBX model from the list.</li>
<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/panasonic_kx_ta_1.png" alt="Panasonic KX-TA/E" />
<li>In the <span class="button" id="list"no_margin">Connection</span> tab select <span class="keyword">No connection required</span> from the <span class="reference">Connection method</span> list.</li>
<li>Finally, click on the <span class="button" id="list"no_margin">Save</span> button.</li>
<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/panasonic_kx_ta_2.png" alt="Panasonic KX-TA/E" />