These instructions help you configure your Panasonic KX-TA/TE phone system to work with TIM Enterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type
TIM Enterprise establishes a serial connection with this PBX.Support Files
Panasonic KX-TD Series.TDTPanasonic KX-TD Series.TDS
Required Tasks
Configure the SMDR outputInstall NetPBX
Configure TIM Enterprise
Configuring the SMDR output
Follow the steps below to configure your Panasonic KX-TA/TE to output SMDR data to TIM Enterprise. The configuration needs to be performed from a Panasonic KX-T7130 phone:
- Set the System Program Switch on the EMSS Control Unit to the position.
- Press followed by the key, then enter your system password.
- Press Programming mode. to enter the
Go to programming code 800 and set each of the fields as shown below. Press and then after each entry in order to move to the next field:
SMDR field Value NL-Code CR+LF Baud Rate 9600 Word Length 8 bits Parity None Stop Bit 1 bit Go to programming code 801 and set each of the fields as shown below. Press and then after each entry in order to move to the next field:
SMDR field Value Page Length Leave as default Skip Perf Leave as default Go to programming code 802 and set each of the fields as shown below. Press and then after each entry in order to move to the next field:
SMDR field Value Outgoing On Incoming On - Set the System Program Switch back to position.
Installing NetPBX
The Panasonic KX-TA/TE phone system sends SMDR information via a serial connection. To collect the call logging data from the serial port and send it to TIM Enterprise, you first need to install the NetPBX software. For setup instructions, click on the link below:
Configuring TIM Enterprise
Once NetPBX is configured and collecting data, log in to TIM Enterprise and perform the following steps:
- Click on the tab.
- Locate the PBX object you want to configure in the Directory, right-click on it and select Properties.
- A new window will open, displaying the general properties of your PBX object. Select Panasonic KX-TD Series from the Data format list and tick the Keep a local backup of data box, as shown below:
- Click on the No connection required from the Connection method list. tab and select
- Click on the
button to apply the settings.