These instructions help you configure your Panasonic KX-TA/
...
TE phone system to work with TIM Enterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Pbxsummary | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HTML |
---|
<a id="Configure the SMDR output"></a> |
Configuring the SMDR output
Follow the steps below to configure your Panasonic KX-TA/TE to output SMDR data to TIM Enterprise. The configuration needs to be performed from a Panasonic KX-T7130 phone:
- Set the System Program Switch on the EMSS Control Unit to the position.
- Press followed by the key, then enter your system password.
- Press to enter the Programming mode.
Go to programming code 800 and set each of the fields as shown below. Press and then after each entry in order to move to the next field:
SMDR field Value NL-Code CR+LF Baud Rate 9600 Word Length 8 bits Parity None Stop Bit 1 bit Go to programming code 801 and set each of the fields as shown below. Press and then after each entry in order to move to the next field:
SMDR field Value Page Length Leave as default Skip Perf Leave as default Go to programming code 802 and set each of the fields as shown below. Press and then after each entry in order to move to the next field:
SMDR field Value Outgoing On Incoming On - Set the System Program Switch back to position.
HTML |
---|
<a id="Install NetPBX"></a> |
Installing NetPBX
The Panasonic KX-TA/TE phone system sends SMDR information via a serial connection. To collect the call logging data from the serial port and send it to TIM Enterprise, you first need to install the netpbx software. For setup instructions, click on the link below:
HTML |
---|
<a id="Configure TIM Enterprise"></a> |
Configuring TIM Enterprise
Once NetPBX is configured and collecting data, log in to TIM Enterprise and perform the following steps:
- Click on the tab.
- Locate the PBX object you want to configure in the Directory, right-click on it and select Properties.
- A new window will open, displaying the general properties of your PBX object. Select Panasonic KX-TD Series from the Data format list and tick the
box, as shown below:Keywordmacro Label Keep a local backup of data Screenshotmacro Border false URL /download/attachments/3801128/panasonic_kx_ta_1.png - Click on the tab and select No connection required from the Connection method list.
- Click on the button to apply the settings.
Screenshotmacro Border false URL /download/attachments/3801128/panasonic_kx_ta_2.png