Configuring your SMDR output

Below you will find instructions on how Follow the instructions below to configure your Samsung DCS to output SMDR data to TIM Plus. You will need to do this from a  The configuration needs to be performed from an LCD handset. Just use the down arrow key to move to each option.

  1. Open
    Referencemacro
    LabelProgramming
    and select 725
    and select 
    Referencemacro
    Label725
    .
  2. Program each option as stated presented below:

    SMDR fieldValue
    Page HeaderYes
    Lines per page1
    Incoming CallYes
    Outgoing CallYes
    Authorise CodeYes
    SMDR Start TimeYes
    In/Out GroupNo
    DND CallsNo
    Wake-Up CallsNo
    Directory NamesNone
    Caller ID DataYes
    Abandoned CallYes
    No of Dial Mask00
    DID Num/NameYes
  3. Now Next, press the SPKR key .Select 804and select 
    Referencemacro
    Label804
    .
  4. Dial 0 and use the arrow keys and select SMDRto select 
    Referencemacro
    LabelSMDR
    .
  5. Now press Press the TRSF key to complete the configuration.
HTML
<a id="Install NetPBX"></a>

...

The Samsung DCS phone system sends SMDR information data via a serial connection. To collect the data from the serial port and send it to TIM Plus, you will first need to install the NetPBX netpbx software. For setup instructions, click on the link below:

Install and configure NetPBX

HTML
<a id="Configure TIM Plus"></a>

...

Once NetPBX is configured and collecting data, log on in to TIM Plus as usual and apply perform the following settingssteps below:

  1. Click on the Directory tab.
  2. Select Choose the site configured during the setup wizard you want to configure and click Properties.
    Screenshotmacro
    Borderfalse
    URLhttp://docs.tri-line.com:8090/download/attachments/4817089/samsung_dcs_1.png
  3. Within In the Site Properties window, select Samsung DCS from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Finally, click Click on the Save button to apply the settings.

...