Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Open Windows Control Panel and select the Administrative Tools icon

  2. Double-click on the Data Sources (ODBC) icon to open the ODBC Data Source Administrator window.

     

    Info

    For a 64 bit system, access the ODBC Data Source Administrator from the following location C:\Windows\SysWOW64\odbcad32.exe

  3. Click on the System DSN tab.
  4. Click on the Add button.
  5. Select SQL Native Client from the driver list and click Finish.
  6. In the Name field, enter swyx.
  7. In the Description field, enter TIM Enterprise link to swyx.
  8. In the Server field, enter the IP address or hostname of your Swyx server.
  9. In the Username field, enter the username for your Swyx database.
  10. In the Password field, enter the password for your Swyx database.
  11. In the Database drop-down list, select swyx.
  12. Click on the Test button to confirm the information you entered is correct and that the connection is successful.
  13. Click on the OK button to close the window.

...

  1. Click on the Directory tab.
  2. Locate the PBX object you want to configure in the Directory, right-click on it and select Properties.
  3. A new window will open. In the General tab, select SWYX V8 from the Data format list and tick the 
    Keywordmacro
    LabelKeep a local backup of data
    box, as shown below:
    Screenshotmacro
    Borderfalse
    URL/download/attachments/3014746/swyxware_2.png
    Image Removed

  4. Click on the Connection tab and select System DSN connection from the Connection method list.
  5. In the DSN field, select swyx from the drop-down list.
  6. In the Frequency field, enter to check for data every five seconds.
  7. In the DB script field, select SWYX V8 from the drop-down list.
  8. Click on the Save button to apply the settings.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/314578117400250/shoretelswyx_3odbc_2.png