You are viewing an old version of this page. View the current version.
Compare with Current ·
View Page History
These instructions should assist in configuring your AYCTelecom IPcts to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.
Connection information | Description |
---|---|
Connection type | IP |
IP Method | The AYCTelecom IPcts sends the SMDR data to the IP address of the TIM Plus machine on a specific TCP port. |
Configuring your SMDR
Below you will find instructions on how to setup the SMDR output using the IPcts Management web page:
- Browse and login to your AYCTelecom IPcts web page.
- Click on the tab
- Click on the tab and configure the fields as below:
- SMDR Server Enabled: Please click on the check box.
- SMDR Server Output: Click on the radio button Network Address.
- SMDR Client IP Address: Enter in the IP address of the machine that TIM Plus is installed on.
- SMDR Client Port: Enter the TCP port number that you want to send the SMDR data to. You can use any free TCP port, we would recommend starting from 9000 and increment it per PBX unit that you are going to send SMDR data from to TIM Plus.
- Click on the button.
- Click on the button at the top of the page.
Below is an example screenshot of the SMDR screen from the AYCTelecom IPcts management web page:
Configuring TIM Plus
Below you will find steps on how to configure TIM Plus to listen for SMDR data from your AYCTelecom IPcts:
- Browse to TIM Plus as normal and login with your credentials.
- Click on the tab.
- Click on the site configured during the setup wizard and click or create a new site and click .
- Within the Site Properties window, select AYCTelecom IPCTS from the PBX model drop-down list.
- In the Connection method field select Listen for connections from PBX from the drop-down list.
- Leave the Host field blank.
- In the Port field enter in the TCP port that was configured on your AYCTelecom IPcts.
- Finally, click on the button.