You are viewing an old version of this page. View the current version.
Compare with Current ·
View Page History
These instructions should assist in configuring your Mitel 3100 to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.
Connection information | Description |
---|---|
Connection type | Serial Output: The Mitel 3100 sends the SMDR information via a serial connection. You will need to directly connect a serial cable from the Upper Serial Port 1 on the Mitel 3100 to the PC that NetPBX is installed and running on. |
Cable configuration | Straight-through. |
Configuring your SMDR
Below you will find the steps to configure your Mitel 3100 to output SMDR via a serials connection:
- Using an RS-232 cable, connect the printer or PC to the call logging (SMDR) port on the front of the controller.
- Launch the system tool.
- Choose from the selection menu.
- Click , click , and then click .
- Set the following parameters:
- Set the Cost per minute to 00. This functionality is not supported in NA systems.
- Set the Minimum call duration to be recorded to 00:00:00.
- Set the Type of calls to All .This should be the default.
- Set the Minimum page length to 1.
- Enable call logging.
- Click .
- You will need to 'commit' your changes before they take effect.
Configuring TIM Plus
Below you will find steps on how to configure TIM Plus to listen for SMDR data from your Mitel 3100:
- Browse to TIM Plus as normal and login with your credentials.
- Click on the tab.
- Click on the site configured during the setup wizard and click or create a new site and click .
- Within the Site Properties window, select Mitel 3100 from the PBX model drop-down list.
- In the Connection method field select No connection required from the drop-down list.
- Finally, click on the button.
Labels: