These instructions help you configure your LG iPECS phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type
TIM Plus establishes a serial connection with this PBX.Support Files
LG iPECS.TDTLG.TDS
Required Tasks
$paramRequiredTask1Connection Type
TIM Plus listens for connections from this PBX.Support Files
LG iPECS.TDTLG.TDS
Required Tasks
$paramRequiredTask1Configuring your SMDR
The LG iPECS by default has SMDR output disabled. Below you will find the programming number codes and the fields that need to be configured.
SMDR Attributes (PGM 177)
Within this window you need to set Info/On-line SMDR to Telnet 1. This will allow TIM Plus to connect to the LG iPECS on TCP port 23 to receive SMDR data.
Below is an example of the SMDR Attributes window:
Printer Port Selection (PGM 175)
Below is an example of the Programming Port Selection window:
Serial output
Installing NetPBX
If your LG iPECS has been configured to send SMDR data via a serial connection, you will first need to install NetPBX software to collect the data from the serial port and send it to Tim Plus. For setup instructions, click on the link below:
Configuring TIM Plus
Once NetPBX is configured and collecting data, log on to TIM Plus as usual and apply the following settings:
- Click on the tab.
- Click on the site configured during the setup wizard and click
. - Within the Site Properties window, select LG iPECS from the PBX model drop-down list.
- In the Connection method field select No connection required from the drop-down list
- Click on the button to apply the settings.
IP output
Configuring TIM Plus
If your LG iPECS has been configured to send the data via TCP/IP, follow the steps below to configure TIM Plus:
- Click on the tab.
- Click on the site configured during the setup wizard and click
. - Within the Site Properties window, select LG iPECS from the PBX model drop-down list.
- In the Connection method field select Listen for connections from PBX from the drop-down list.
- In the Host field enter in the IP Address of your LG iPECS.
- In the Port field enter in 23.
- Click on the button to apply the settings.
These instructions should assist in configuring your LG iPECS to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.
Connection information | Description |
---|---|
Connection type | Serial Output or IP: If you have configured the LG iPECS to send the SMDR information via a serial connection, you will need to directly connect a serial cable from the LG iPECS to the PC that NetPBX is installed and running on. |
Cable configuration | Null-modem/Crossover. |
IP method | If the LG iPECS is configured to send the SMDR information via TCP/IP, the actual installation of TIM Plus can be anywhere on the network that the PBX is connected to. The LG iPECS will need to be configured to output SMDR data via TCP/IP so TIM Plus can connect to it. TIM Plus will connect to the LG iPECS on TCP port 23. |
Configuring your SMDR
The LG iPECS by default has SMDR output disabled. Below you will find the programming number codes and the fields that need to be configured.
SMDR Attributes (PGM 177)
Within this window you need to set Info/On-line SMDR to Telnet 1. This will allow TIM Plus to connect to the LG iPECS on TCP port 23 to receive SMDR data.
Below is an example of the SMDR Attributes window:
Printer Port Selection (PGM 175)
Below is an example of the Programming Port Selection window:
Configuring TIM Plus
Below you will find steps on how to configure TIM Plus to listen for SMDR data from your LG iPECS:
- Browse to TIM Plus as normal and login with your credentials.
- Click on the tab.
- Click on the site configured during the setup wizard and click or create a new site and click .
- Within the Site Properties window, select LG iPECS from the PBX model drop-down list.
- In the Connection method field select Listen for connections from PBX from the drop-down list.
- In the Host field enter in the IP Address of your LG iPECS.
- In the Port field enter in 23.
- Finally, click on the button.