Connection Type
TIM Plus establishes a serial connection with this PBX.Support Files
NEC Aspire.TDTNEC Aspire.TDS
Required Tasks
$paramRequiredTask1Connection Type
TIM Plus establishes a TCP connection to this PBX.Support Files
NEC Aspire.TDTNEC Aspire.TDS
Required Tasks
$paramRequiredTask1Configuring your SMDR
Below you will find details on how to configure the SMDR output on the NEC Aspire. The programming will need to be done via PC Pro/Web Pro:
- Login to your PC Pro/Web Pro.
As the NEC Aspire has multiple ways of sending SMDR Data, below are the configuration settings based on each adaptor:
Adaptor Programming code Value Description NTCPU - IP 10-12-01 IP address that TIM Plus will connect to. NTUCPU Network Setup - IP Address. 10-20-01 TCP port that TIM Plus will connect to. We recommend using 9000 and increment it for each NEC Aspire you configure. LAN Setup for External Equipment. NTCPU - Serial 10-21-02 1 NTCPU Hardware Setup - Baud Rate for Com Port. In this screen you need to configure the baud rate for the com port, you have three options, 0(4800), 1(9600) and 2(38400). 35-01-01 1 SMDR Options - Output Port Type. CTA/CTU - Serial 15-02-19 1 Multi-Line Telephone Basic Data Setup - CTA/CTU Data Communication Module. 15-02-20 1 Multi-Line Telephone Basic Data Setup - Baud Rate for CTA/CTU port. In this screen you need to configure the baud rate for the com port. You have three options, 0(4800), 1(9600) and 2(19200). 35-01-01 4 SMDR Options - Output Port Type. 35-01-02 Extension number that the CTA/CTU adaptor is attached to. SMDR Options - Output Destination Number. You also need to configure the following programming codes:
Programming code Value Description 14-01-06 1 Basic Trunk Data Setup - SMDR Print. 15-01-03 1 Basic Extension Data Setup - SMDR Print. 35-01-03 0 SMDR Options - Header Language. 35-01-04 0 SMDR Options - Omit (Mask) Digits. 35-01-05 0 SMDR Options - Minimum Number of SMDR Digits. 35-01-06 0 SMDR Options - Minimum Call Duration. 35-01-07 0 SMDR Options - Minimum Ringing Time. 35-01-08 Default SMDR Options - SMDR Format. 35-02-01 0 SMDR Output Options - Toll Restricted Call. 35-02-02 1 SMDR Output Options - PBX Calls. 35-02-03 1 SMDR Output Options - Display Trunk Name or Numbers. 35-02-04 0 SMDR Output Options - Daily Summary. 35-02-05 0 SMDR Output Options - Weekly Summary. 35-02-06 0 SMDR Output Options - Monthly Summary. 35-02-08 1 SMDR Output Options - Incoming calls. 35-02-09 0 SMDR Output Options - Print Name or Numbers. 35-02-10 0 SMDR Output Options - All Lines Busy (ALB) Output. 35-02-12 0 SMDR Output Options - DID Table Name Output. 35-02-13 1 SMDR Output Options - CLI Output when DID to Trunk. 35-02-14 1 SMDR Output Options - Date. 35-02-15 1 SMDR Output Options - CLI/DID Number Switching. 35-02-16 1 SMDR Output Options - Print Trunk Name or Received Dialled Number. 35-02-17 0 SMDR Output Options - Print Account Code or Caller ID Name. 35-02-18 Default SMDR Output Options - Caller ID Name Output Method. 80-05-01 1 Date Format for SMDR and System Reports.
Serial output
Installing NetPBX
If your LG iPECS has been configured to send SMDR data via a serial connection, you will first need to install NetPBX software to collect the data from the serial port and send it to Tim Plus. For setup instructions, click on the link below:
Configuring TIM Plus
Once NetPBX is configured and collecting data, log on to TIM Plus as usual and apply the following settings:
- Click on the tab.
- Click on the site configured during the setup wizard and click
.
These instructions should assist in configuring your NEC Aspire to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.
Connection information | Description |
---|---|
Connection type | Serial Output or IP: To use a serial connection you will need to have a CTA/CTU adaptor or a NTCPU adaptor installed on your NEC Aspire. You will need to connect a serial cable from the adaptor to the PC that NetPBX is installed and running on. |
Cable configuration | Straight-through for the CTA/CTU Adaptor and Null-modem/Crossover for the NTCPU serial adaptor. |
IP method | If the NEC Aspire is configured to send the SMDR information via TCP/IP, the actual installation of TIM Plus can be anywhere on the network that the PBX is connected to. The NEC Aspire will need to be configured to output SMDR data via TCP/IP so TIM Plus can connect to it. TIM Plus will connect to the NEC Aspire on TCP port 23. |
Configuring your SMDR
Below you will find details on how to configure the SMDR output on the NEC Aspire. The programming will need to be done via PC Pro/Web Pro:
- Login to your PC Pro/Web Pro.
- As the NEC Aspire has multiple ways of sending SMDR Data, below are the configuration settings based on each adaptor:
- You also need to configure the following programming codes:
Adaptor | Programming code | Value | Description |
---|---|---|---|
NTCPU - IP | 10-12-01 | IP address that TIM Plus will connect to. | NTUCPU Network Setup - IP Address. |
10-20-01 | TCP port that TIM Plus will connect to. We recommend using 9000 and increment it for each NEC Aspire you configure. | LAN Setup for External Equipment. | |
NTCPU - Serial | 10-21-02 | 1 | NTCPU Hardware Setup - Baud Rate for Com Port. In this screen you need to configure the baud rate for the com port, you have three options, 0(4800), 1(9600) and 2(38400). |
35-01-01 | 1 | SMDR Options - Output Port Type. | |
CTA/CTU - Serial | 15-02-19 | 1 | Multi-Line Telephone Basic Data Setup - CTA/CTU Data Communication Module. |
15-02-20 | 1 | Multi-Line Telephone Basic Data Setup - Baud Rate for CTA/CTU port. In this screen you need to configure the baud rate for the com port. You have three options, 0(4800), 1(9600) and 2(19200). | |
35-01-01 | 4 | SMDR Options - Output Port Type. | |
35-01-02 | Extension number that the CTA/CTU adaptor is attached to. | SMDR Options - Output Destination Number. |
Programming code | Value | Description |
---|---|---|
14-01-06 | 1 | Basic Trunk Data Setup - SMDR Print. |
15-01-03 | 1 | Basic Extension Data Setup - SMDR Print. |
35-01-03 | 0 | SMDR Options - Header Language. |
35-01-04 | 0 | SMDR Options - Omit (Mask) Digits. |
35-01-05 | 0 | SMDR Options - Minimum Number of SMDR Digits. |
35-01-06 | 0 | SMDR Options - Minimum Call Duration. |
35-01-07 | 0 | SMDR Options - Minimum Ringing Time. |
35-01-08 | Default | SMDR Options - SMDR Format. |
35-02-01 | 0 | SMDR Output Options - Toll Restricted Call. |
35-02-02 | 1 | SMDR Output Options - PBX Calls. |
35-02-03 | 1 | SMDR Output Options - Display Trunk Name or Numbers. |
35-02-04 | 0 | SMDR Output Options - Daily Summary. |
35-02-05 | 0 | SMDR Output Options - Weekly Summary. |
35-02-06 | 0 | SMDR Output Options - Monthly Summary. |
35-02-08 | 1 | SMDR Output Options - Incoming calls. |
35-02-09 | 0 | SMDR Output Options - Print Name or Numbers. |
35-02-10 | 0 | SMDR Output Options - All Lines Busy (ALB) Output. |
35-02-12 | 0 | SMDR Output Options - DID Table Name Output. |
35-02-13 | 1 | SMDR Output Options - CLI Output when DID to Trunk. |
35-02-14 | 1 | SMDR Output Options - Date. |
35-02-15 | 1 | SMDR Output Options - CLI/DID Number Switching. |
35-02-16 | 1 | SMDR Output Options - Print Trunk Name or Received Dialled Number. |
35-02-17 | 0 | SMDR Output Options - Print Account Code or Caller ID Name. |
35-02-18 | Default | SMDR Output Options - Caller ID Name Output Method. |
80-05-01 | 1 | Date Format for SMDR and System Reports. |
Configuring TIM Plus
Below you will find steps on how to configure TIM Plus to listen for SMDR data from your NEC Aspire:
- Browse to TIM Plus as normal and login with your credentials.
- Click on the tab.
- Click on the site configured during the setup wizard and click or create a new site and click .
- Within the Site Properties window, select NEC Aspire from the PBX model drop-down list.
- In the Connection method field select Actively connect to PBX from the drop-down list.
- In the Host field enter the IP Address of your NEC Aspire.
- In the Port field enter in the port configured in programming code 10-20-01.
- Leave the Username and Password fields blank.
- In the Connection script field select Generic Simple from the drop-down list.
- Finally, click on the button.