Connection Type
  TIM Plus establishes a serial connection with this PBX.

Support Files
  NEC Aspire.TDT
  NEC Aspire.TDS
Required Tasks
  $paramRequiredTask1
or
Connection Type
  TIM Plus establishes a TCP connection to this PBX.

Support Files
  NEC Aspire.TDT
  NEC Aspire.TDS
Required Tasks
  $paramRequiredTask1

Configuring your SMDR

Below you will find details on how to configure the SMDR output on the NEC Aspire. The programming will need to be done via PC Pro/Web Pro:

  1. Login to your PC Pro/Web Pro.
  2. As the NEC Aspire has multiple ways of sending SMDR Data, below are the configuration settings based on each adaptor:

    AdaptorProgramming codeValueDescription
    NTCPU - IP10-12-01IP address that TIM Plus will connect to.NTUCPU Network Setup - IP Address.
    10-20-01TCP port that TIM Plus will connect to. We recommend using 9000 and increment it for each NEC Aspire you configure.LAN Setup for External Equipment.
    NTCPU - Serial10-21-021NTCPU Hardware Setup - Baud Rate for Com Port. In this screen you need to configure the baud rate for the com port, you have three options, 0(4800), 1(9600) and 2(38400).
    35-01-011SMDR Options - Output Port Type.
    CTA/CTU - Serial15-02-191Multi-Line Telephone Basic Data Setup - CTA/CTU Data Communication Module.
    15-02-201Multi-Line Telephone Basic Data Setup - Baud Rate for CTA/CTU port. In this screen you need to configure the baud rate for the com port. You have three options, 0(4800), 1(9600) and 2(19200).
    35-01-014SMDR Options - Output Port Type.
    35-01-02Extension number that the CTA/CTU adaptor is attached to.SMDR Options - Output Destination Number.
  3. You also need to configure the following programming codes:

    Programming codeValueDescription
    14-01-061Basic Trunk Data Setup - SMDR Print.
    15-01-031Basic Extension Data Setup - SMDR Print.
    35-01-030SMDR Options - Header Language.
    35-01-040SMDR Options - Omit (Mask) Digits.
    35-01-050SMDR Options - Minimum Number of SMDR Digits.
    35-01-060SMDR Options - Minimum Call Duration.
    35-01-070SMDR Options - Minimum Ringing Time.
    35-01-08DefaultSMDR Options - SMDR Format.
    35-02-010SMDR Output Options - Toll Restricted Call.
    35-02-021SMDR Output Options - PBX Calls.
    35-02-031SMDR Output Options - Display Trunk Name or Numbers.
    35-02-040SMDR Output Options - Daily Summary.
    35-02-050SMDR Output Options - Weekly Summary.
    35-02-060SMDR Output Options - Monthly Summary.
    35-02-081SMDR Output Options - Incoming calls.
    35-02-090SMDR Output Options - Print Name or Numbers.
    35-02-100SMDR Output Options - All Lines Busy (ALB) Output.
    35-02-120SMDR Output Options - DID Table Name Output.
    35-02-131SMDR Output Options - CLI Output when DID to Trunk.
    35-02-141SMDR Output Options - Date.
    35-02-151SMDR Output Options - CLI/DID Number Switching.
    35-02-161SMDR Output Options - Print Trunk Name or Received Dialled Number.
    35-02-170SMDR Output Options - Print Account Code or Caller ID Name.
    35-02-18DefaultSMDR Output Options - Caller ID Name Output Method.
    80-05-011Date Format for SMDR and System Reports.

Serial output

Installing NetPBX

If your NEC Aspire has been configured to send SMDR data via a serial connection, you will first need to install NetPBX software to collect the data from the serial port and send it to Tim Plus. For setup instructions, click on the link below:

Install and configure NetPBX

Configuring TIM Plus

Once NetPBX is configured and collecting data, log on to TIM Plus as usual and apply the following settings:

  1. Click on the Directory tab.
  2. Click on the site configured during the setup wizard and click Properties.

  3. Within the Site Properties window, select NEC Aspire from the PBX model drop-down list.
  4. In the Connection method field select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.

IP output

Configuring TIM Plus

If your NEC Aspire has been configured to send the data via TCP/IP, follow the steps below to configure TIM Plus:

  1. Click on the Directory tab.
  2. Click on the site configured during the setup wizard and click Properties.

  3. Within the Site Properties window, select NEC Aspire from the PBX model drop-down list.
  4. In the Connection method field select Actively connect to PBX from the drop-down list.
  5. In the Host field enter the IP Address of your NEC Aspire.
  6. In the Port field enter in the port configured in programming code 10-20-01.
  7. Leave the Username and Password fields blank.
  8. In the Connection script field select Generic Simple from the drop-down list.
  9. Finally, click on the Save button to apply the changes.

 

These instructions should assist in configuring your NEC Aspire to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.

Connection information Description
Connection type Serial Output or IP: To use a serial connection you will need to have a CTA/CTU adaptor or a NTCPU adaptor installed on your NEC Aspire. You will need to connect a serial cable from the adaptor to the PC that NetPBX is installed and running on.
Cable configuration Straight-through for the CTA/CTU Adaptor and Null-modem/Crossover for the NTCPU serial adaptor.
IP method If the NEC Aspire is configured to send the SMDR information via TCP/IP, the actual installation of TIM Plus can be anywhere on the network that the PBX is connected to. The NEC Aspire will need to be configured to output SMDR data via TCP/IP so TIM Plus can connect to it. TIM Plus will connect to the NEC Aspire on TCP port 23.

Configuring your SMDR

Below you will find details on how to configure the SMDR output on the NEC Aspire. The programming will need to be done via PC Pro/Web Pro:

  1. Login to your PC Pro/Web Pro.
  2. As the NEC Aspire has multiple ways of sending SMDR Data, below are the configuration settings based on each adaptor:
  3. Adaptor Programming code Value Description
    NTCPU - IP 10-12-01 IP address that TIM Plus will connect to. NTUCPU Network Setup - IP Address.
    10-20-01 TCP port that TIM Plus will connect to. We recommend using 9000 and increment it for each NEC Aspire you configure. LAN Setup for External Equipment.
    NTCPU - Serial 10-21-02 1 NTCPU Hardware Setup - Baud Rate for Com Port. In this screen you need to configure the baud rate for the com port, you have three options, 0(4800), 1(9600) and 2(38400).
    35-01-01 1 SMDR Options - Output Port Type.
    CTA/CTU - Serial 15-02-19 1 Multi-Line Telephone Basic Data Setup - CTA/CTU Data Communication Module.
    15-02-20 1 Multi-Line Telephone Basic Data Setup - Baud Rate for CTA/CTU port. In this screen you need to configure the baud rate for the com port. You have three options, 0(4800), 1(9600) and 2(19200).
    35-01-01 4 SMDR Options - Output Port Type.
    35-01-02 Extension number that the CTA/CTU adaptor is attached to. SMDR Options - Output Destination Number.
  4. You also need to configure the following programming codes:
  5. Programming code Value Description
    14-01-06 1 Basic Trunk Data Setup - SMDR Print.
    15-01-03 1 Basic Extension Data Setup - SMDR Print.
    35-01-03 0 SMDR Options - Header Language.
    35-01-04 0 SMDR Options - Omit (Mask) Digits.
    35-01-05 0 SMDR Options - Minimum Number of SMDR Digits.
    35-01-06 0 SMDR Options - Minimum Call Duration.
    35-01-07 0 SMDR Options - Minimum Ringing Time.
    35-01-08 Default SMDR Options - SMDR Format.
    35-02-01 0 SMDR Output Options - Toll Restricted Call.
    35-02-02 1 SMDR Output Options - PBX Calls.
    35-02-03 1 SMDR Output Options - Display Trunk Name or Numbers.
    35-02-04 0 SMDR Output Options - Daily Summary.
    35-02-05 0 SMDR Output Options - Weekly Summary.
    35-02-06 0 SMDR Output Options - Monthly Summary.
    35-02-08 1 SMDR Output Options - Incoming calls.
    35-02-09 0 SMDR Output Options - Print Name or Numbers.
    35-02-10 0 SMDR Output Options - All Lines Busy (ALB) Output.
    35-02-12 0 SMDR Output Options - DID Table Name Output.
    35-02-13 1 SMDR Output Options - CLI Output when DID to Trunk.
    35-02-14 1 SMDR Output Options - Date.
    35-02-15 1 SMDR Output Options - CLI/DID Number Switching.
    35-02-16 1 SMDR Output Options - Print Trunk Name or Received Dialled Number.
    35-02-17 0 SMDR Output Options - Print Account Code or Caller ID Name.
    35-02-18 Default SMDR Output Options - Caller ID Name Output Method.
    80-05-01 1 Date Format for SMDR and System Reports.

Configuring TIM Plus

Below you will find steps on how to configure TIM Plus to listen for SMDR data from your NEC Aspire:

  1. Browse to TIM Plus as normal and login with your credentials.
  2. Click on the Directory tab.
  3. Click on the site configured during the setup wizard and click Propertiesor create a new site and click Properties.
  4. NEC Aspire
  5. Within the Site Properties window, select NEC Aspire from the PBX model drop-down list.
  6. In the Connection method field select Actively connect to PBX from the drop-down list.
  7. In the Host field enter the IP Address of your NEC Aspire.
  8. In the Port field enter in the port configured in programming code 10-20-01.
  9. Leave the Username and Password fields blank.
  10. In the Connection script field select Generic Simple from the drop-down list.
  11. Finally, click on the Save button.