These instructions help you configure your Alcatel OmniPCX Enterprise phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type
TIM Plus establishes a TCP connection to this PBX.Support Files
Alcatel OmniPCX Enterprise.TDTAlcatel OmniPCX Enterprise.TDS
Required Tasks
Configure the SMDR outputConfigure TIM Plus
Configuring your SMDR
Below you will find instructions on how to configure the SMDR output via an IP connection. These instructions are taken from the Alcatel OmniPCX Enterprise manual:
Connect to your PBX via telnet and follow the steps below:
- Applications ( )
- Accounting ( )
- Review/Modify ( )
- All Instance ( )
- Realtime ticket Output: Set this to ethernet. Note that if you don't have appropriate license, you can only select V24 (serial) here.
- Save changes and exit
The table below presents a summary of data output from Alcatel:
Configuring TIM Plus
Below you will find steps on how to configure TIM Plus to collect the SMDR data from your Alcatel OmniPCX Enterprise:
- Click on the tab.
- Click on the site configured during the setup wizard and click
. - Within the Site Properties window, select Alcatel OmniPCX Enterprise from the PBX model drop-down list.
- In the Connection method field, select Actively connect to PBX from the drop-down list.
- In the Host field, enter the IP Address of your Alcatel OmniPCX Enterprise.
- In the Port field, enter in 2533.
- Leave the Username and Password fields blank.
- In the Connection script field select Alcatel OmniPCX Enterprise 7.1+ from the drop-down list.
- Finally, click on the button.