These instructions should assist in configuring your BT Versatility to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.
Connection Type
TIM Plus establishes a serial connection with this PBX.Support Files
BT Versatility.TDTBT Versatility.TDS
Required Tasks
Configure the SMDR outputInstall NetPBX
Configure TIM Plus
Configuring your SMDR
These instructions should assist in configuring your BT Versatility to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.
The interface to the printer or PC should be serial V24/RS232-C and should meet the following specifications: Speed – 4800, 9600, 19200, 38400 or 115,200 bps. Data - 8 bits (no parity). The BT Versatility has an in-built buffer to store the last 500 call records. This buffer can be output to the serial port as required. This option is selected in the system programming. An X-on X-off signal can be enabled which allows the switch to detect if a device on the serial port, which supports X-on X-off is receiving the data. Another option allows the last four digits of the dialled number to be masked. This is 'Restricted call logging'.
Installing NetPBX
The BT Versatility phone system sends SMDR information via a serial connection. To collect the data from the serial port and send it to TIM Plus, you will first need to install the NetPBX software For setup instructions, click on the link below:
Configuring TIM Plus
Once NetPBX is configured and collecting data, log on to TIM Plus as usual and apply the following settings:
- Click on the tab.
- Select the site configured during the setup wizard and click
. - Within the Site Properties window, select BT Versatility from the PBX model drop-down list.
- In the Connection method field, select No connection required from the drop-down list.
- Cliick on the button to apply the settings.