The NEC NEAX can be configured to send the SMDR data via a serial or an IP connection.  Click on one of the links below for your preferred connection method.

 

 

These instructions should assist in configuring your NEC NEAX to work with TIM Plus. If you are not familiar with PBX configuration, please contact your system maintainer.

Connection information Description
Connection type Serial Output or IP: If you have configured the NEC NEAX to send the SMDR information via a serial connection, you will need to directly connect a serial cable from the NEC NEAX to the PC that NetPBX is installed and running on.
Cable configuration Null-mode/Crossover or Straight-through. Please check your NEC NEAX manual.
IP method If the NEC NEAX is configured to send the SMDR information via TCP/IP, the actual installation of TIM Plus can be anywhere on the network that the PBX is connected to. The NEC NEAX will need to be configured to output SMDR data via TCP/IP so TIM Plus can connect to it. TIM Plus will connect to the NEC NEAX on TCP port 2599.

You will need to speak to your system maintainer to enable the SMDR output.

Configuring your Serial connection

Using the CAT (Customer Administration Terminal) in the system-programming mode, enter the following settings:

Field name Details
CM40 Output port & attributes defaults: 9600 baud, 8 data bits, no parity, 2 stop bits, DTR/RTS flow control.
CM13+05 Enable SMDR for incoming calls to required stations.
CM13+06 Enable SMDR for outgoing calls to required stations.
CM35+14 Enable SMDR for outgoing calls to required trunk routes.
CM35+49 Enable SMDR for incoming calls to required trunk routes.
CM08 If SMDR for incoming calls is enabled, specify whether it applies to all incoming calls or only to those with Account Codes. Include ANI/Caller ID for incoming calls.

NOTE 1: The ANI/Caller ID is required to provide SMDR for incoming calls, even if this feature is enabled by CM13+05 and CM35+49.

NOTE 2: Use CDR formats #501 (2400 IMS), #505 (2000 IPS), #506 (2000 IVS).

Configuring TIM Plus

Below you will find steps on how to configure TIM Plus to listen for SMDR data from your NEC NEAX:

  1. Browse to TIM Plus as normal and login with your credentials.
  2. Click on the Directory tab.
  3. Click on the site configured during the setup wizard and click Propertiesor create a new site and click Properties.
  4. NEC NEAX
  5. Within the Site Properties window, select NEC NEAX from the PBX model drop-down list.
  6. In the Connection method field select Actively connect to PBX from the drop-down list.
  7. In the Host field enter the IP Address of your NEC NEAX.
  8. In the Port field enter in 2599.
  9. Leave the Username and Password fields blank.
  10. In the Connection script field select NEC NEAX 2000 IVS from the drop-down list.
  11. Finally, click on the Save button.