These instructions help you configure your LG IPLDK phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Connection Type
  TIM Plus establishes a serial connection with this PBX.

Support Files
  LG IPLDK.TDT
  LG.TDS
Required Tasks
  Configure the SMDR output
  Install NetPBX
  Configure TIM Plus

Configuring your SMDR output

The SMDR output on the LG IPLDK is disabled by default. To enable the output, you need to amend the following settings in the programming sections below:

Print Serial Port Selection (PGM 175)

In the Print Serial Port Selection (PGM 175) window, set Info/On-line SMDR to Telnet 1 to allow connections on TCP port 23.


SMDR Attributes (PGM 177)

Save Enable: This needs to be disabled
Print Enable: This needs to be enabled
SMDR Record Call Type: This needs to be set to 'All Calls'
Records In Detail: This needs to be enabled
Print Incoming Call: This needs to be enabled
Print Lost Call: This needs to be enabled
SMDR Dial Digit Hidden: Leave this as the default which is '0'
SMDR Currency Unit: Leave this as the default which is blank
SMDR Cost Per Metering Pulse: Leave this as the default which is blank
SMDR Fraction: Leave this as the default which is '0'
SMDR Start Time: Leave this as the default which is '0'
SMDR Hidden Digit: Leave this as the default which is 'Right'
Long Distance Call Digit Counter: Leave this as the default which is '0'
Long Distance Code (Max 2 Digits): Leave this as the default
MSN Print on SMDR: This needs to be disabled
Print Caller Number: This needs to be disabled


ISDN Attributes (PGM 200)

Enable the CLI Print to serial field, as shown the ISDN Attributes window below:


 

Installing NetPBX

Install and configure NetPBX

 

Configuring TIM Plus

Once NetPBX is configured and collecting data, log in to TIM Plus and perform the following steps:

  1. Click on the Directory tab.
  2. Choose the sites you want to configure and click Properties.

  3. In the Site Properties window, select LG IPLDK from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.

 

Labels: