These instructions help you configure your LG IPLDK phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type
TIM Plus establishes a TCP connection to this PBX.Support Files
LG IPLDK.TDTLG.TDS
Required Tasks
Configure the SMDR outputConfigure TIM Plus
Configuring your SMDR output
The SMDR output on the LG IPLDK is disabled by default. To enable the output, you need to amend the following settings in the programming sections below:
Print Serial Port Selection (PGM 175)
In this window, set Info/On-line SMDR to Telnet 1 to send call logging data to TIM Plus over TCP to port 23..
Here is an example of a populated Print Serial Port Selection screen:
SMDR Attributes (PGM 177)
Below is an example of the SMDR Attributes window:
ISDN Attributes (PGM 200)
Below is an example of the ISDN Attributes window. Please note that the CLI Print to serial field needs to be enabled.
Configuring TIM Plus
If your LG IPLDK has been configured to send the data via TCP/IP, follow the steps below to configure TIM Plus:
- Click on the tab.
- Click on the site configured during the setup wizard and click
. - Within the Site Properties window, select LG IPLDK from the PBX model drop-down list.
- In the Connection method field, select Actively connect to PBX from the drop-down list.
- In the Host field, enter the IP address of your LG IPLDK.
- In the Port field, enter in 23.
- Leave the Username and Password fields blank.
- In the Connection script field, select Generic Simple from the drop-down list.
- Click on the button to apply the settings.