These instructions help you configure your Siemens OpenOffice phone system to work with TIM Enterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type

Support Files



Required Tasks




Configuring your SMDR output
By default, the SMDR output of a Siemens OpenOffice phone system is not enabled. For information about how to configure the output for incoming, outgoing and internal calls, contact your system maintainer.
Configure the interface file
Follow the steps below to configure the interface file to establish an HTTPS connection with your Siemens OpenOffice:
- Open the Siemens OpenOffice.TDT file, located by default in C:\Program Files (x86)\Tri-Line\TIM Enterprise\config.
- Edit the file to point to the IP address of your Siemens OpenOffice and enter the relevant username and password, as shown below.
- Remove the apostrophe (') in front of the edited fields, to enable the configuration. An example of a configured interface file is shown below:
Setting up a DSN connection
To enable TIM Enterprise to work with the Siemens OpenOffice, you first need to set up a DSN connection, by following the steps below:
- Open Windows Control Panel.
- Double-click on the icon.
- Double-click on the icon.
- Click on the tab.
- Click on the button.
- Select Native from the driver list and click .
- In the Data source name field enter Siemens OpenOffice.
- Click on the button to save the changes.
An example of an ODBC entry is shown below:
Configuring TIM Enterprise
Once the DSN connection has been set up, log in to TIM Enterprise and perform the following steps:
- Click on the tab.
- Choose the PBX object you want to configure and click Properties.
- A new window will open. In the Siemens OpenOffice from the Data format list and tick the Keep a local backup of data box, as shown below:
- In the System DSN connection from the Connection method list. tab, select
- In the DSN field, select Siemens OpenOffice from the drop-down list.
- In the Frequency field, enter 5 to check for data every five seconds.
- In the DB script field, select Siemens from the drop-down list.
- Click on the