These instructions help you configure your NEC NEAX phone system to work with TIM Enterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type
TIM Enterprise establishes a serial connection with this PBX.Support Files
NEC NEAX.TDTNEC NEAX.TDS
Required Tasks
Configure the SMDR outputInstall NetPBX
Configure TIM Enterprise
Configuring your SMDR output
Using the Customer Administration Terminal (CAT), enter the following settings in the system-programming mode:
Field name | Details | ||
---|---|---|---|
CM40 | Default output port and attributes: 9600 baud, 8 data bits, no parity, 2 stop bits, DTR/RTS flow control. | ||
CM13+05 | Enable SMDR for incoming calls to required stations. | ||
CM13+06 | Enable SMDR for outgoing calls to required stations. | ||
CM35+14 | Enable SMDR for outgoing calls to required trunk routes. | ||
CM35+49 | Enable SMDR for incoming calls to required trunk routes. | ||
CM08 | If SMDR for incoming calls is enabled, specify whether the setting applies to all incoming calls or only to those that use account codes. Also, include ANI/Caller ID for incoming calls.
|
Installing NetPBX
To capture SMDR data from your NEC NEAX using a serial connection, you first need to install the NetPBX software to collect the data from the serial port and send it to TIM Enterprise. For setup instructions, click on the link below:
Configuring TIM Enterprise
Once NetPBX is configured and collecting data, log in to TIM Enterprise and perform the following steps:
- Click on the tab.
- Choose the PBX object you want to configure and click Properties.
- A new window will open. In the NEC NEAX from the Data format list and tick the Keep a local backup of data box, as shown below:
tab, select - In the No connection required from the Connection method list. tab, select
- Click on the
button to apply the settings.