These instructions help you configure your LG iPECS phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type
TIM Enterprise establishes a serial connection with this PBX.Support Files
LG iPECS.TDTLG.TDS
Required Tasks
Configure the SMDR outputInstall NetPBX
Configure TIM Plus
Configure the SMDR output
The SMDR output in LG iPECS is disabled by default. To enable the output, you need to amend the following settings in the programming sections below:
SMDR Attributes (PGM 177)
Field | Description |
---|---|
Save Enable | Leave this as the default, which is unticked |
Print Enable | This needs to be enabled by clicking on the check box |
SMDR Record Call Type | This needs to be set to 'All Calls', you will need to select this from the drop-down list |
Records In Detail | This needs to be enabled by clicking on the check box |
Print Incoming Call | This needs to be enabled by clicking on the check box |
Print Lost Call | This needs to be enabled by clicking on the check box |
SMDR Dial Digit Hidden | Leave this as the default which is '0' |
SMDR Currency Unit | Leave this as the default which is blank |
SMDR Cost Per Metering Pulse | Leave this as the default which is blank |
SMDR Fraction | Leave this as the default which is '0' |
SMDR Start Time | Leave this as the default which is '0' |
SMDR Hidden Digit | Leave this as the default which is 'Right' |
Long Distance Call Digit Counter | Leave this as the default which is '0' |
Long Distance Code (Max 2 Digits) | Leave this as the default |
MSN Print on SMDR | Leave this is the default which is unticked |
Print Caller Number | This needs to be enabled by clicking on the check box |
Here is an example of a populated SMDR Attributes screen:
Printer Port Selection (PGM 175)
In the Printer Port Selection (PGM 175) window, set Info/On-line SMDR to COM1/COM2 to send call logging data by serial port.
ISDN Attributes (PGM 200)
To enable CLI information in the call records produced by your LG iPECS, you need to set the CLI Print To Serial to ON, as shown below:
Installing NetPBX
If your LG iPECS has been configured to send SMDR data via a serial connection, you first need to install the NetPBX software to collect data from the serial port and send it to TIM Plus. For setup instructions, click on the link below:
Configuring TIM Enterprise
Once NetPBX is configured and collecting data, log in to TIM Enterprise and perform the following steps:
- Click on the tab.
- Choose the PBX object you want to configure and click Properties.
- A new window will open. In the AGFEO AC-AS Series from the Data format list and tick the Keep a local backup of data box, as shown below:
tab, select - In the No connection required from the Connection method list. tab, select
- Click on the
button to apply the settings.