These instructions help you configure your Unify OpenScape Busines phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type
TIM Plus listens for connections from this PBX.Support Files
Unify OpenScape Business.TDSUnify OpenScape Business.TDT
Required Tasks
Configure the SMDR outputConfigure TIM Plus
Configuring the SMDR output
Enabling the SMDR output
Follow the instructions below to configure the SMDR output in your phone system. These instructions are taken from the Unify OpenScape Business manual:
- Log on to OpenScape Business Assistant and click on
-> -> , as shown below: - Click Call Detail Recording wizard. to start the
- In the new window that opens, tick the Activate Call Charge Recording to enable the CDR output, as shown below:
Sending the SMDR via TCP/IP
By default, the Unify OpenScape Business phone system send its SMDR output via HTTPS. To send the data via a TCP/IP, follow the steps below:
- Log on to OpenScape Business Assitant with Expert profile
- Click on -> in the navigation tree
- Click on Basic Settings -> Call charges -> Call charges output format
- In the CDR system section, select LAN-TCP-Client from the drop-down list
- In the TCP-Client field, enter the IP address of the PC running TIM Plus and the port number you want to use for the SMDR output, as shown in the screenshot below:
If the HiPath 3K database was simply converted and not retyped, no change will be required, since both the old and the new database will use ; as a separator. If the database was retyped, the new platforms default to |separator. This is the most notable in a networked environment where the same template must be used.
However, the | separator cannot be set in the new WBM tool, and can only be configured using the Manager E, as shown below:
Configuring TIM Plus
Follow the steps below to configure TIM Plus to listen for SMDR data from your telephone system:
- Click on the tab.
- Choose the site you want to configure and click
. - In the Site Properties window, select Unify OpenScape Business from the PBX model drop-down list.
- In the Connection method field, select Listen for connections from PBX from the drop-down list.
- Leave the Host field blank.
- In the Port field, enter the port number configured in the telephone system.
- Click on the button to apply the settings